multiFiltratePRO

multiFiltratePRO

A perfect fit for every team

  • Ergonomic design
  • Easy application of CRRT
  • Integrated Ci-Ca anticoagulation
  • Key features
  • Integrated Ci-Ca
  • Therapy kits
  • Technology

Key features at a glance

Integrated Ci-Ca citrate anticoagulation

Statement on the Ci-Ca protocol:

[It] enabled an effective treatment of acute renal failure and excellent control on the acid–base status as well on the systemic ionised calcium in combination with negligible clotting issues.2

Intelligent software support

Ci-Ca protocol included in the software

multiFiltratePRO CiCa HD screen
Screen during Ci-Ca CVVHD application provides key information from the Ci-Ca protocol
Supports the user with expert information and features
For routine adjustments of the Ci-Ca therapy, information from the protocol can easily be retrieved on the screen
In case of certain values set outside the standard range, the multiFiltratePRO makes the user aware of potentially risky clinical situations

Dedicated hardware components for citrate anticoagulation

Clear allocation of functionality

Dedicated pumps for citrate and calcium keep the syringe pump available for heparin application if needed during Ci-Ca therapy. Separate level detectors and drip counters enable timely detection of empty bags, preventing air being transported downstream and enabling a smooth continuation of the treatment. During bag changes (dialysate, substituate, filtrate) the citrate infusion continues for a reliable period of time. This helps to avoid early coagulation of the system

Nurse operating multiFiltratePRO device
Nurse operating multiFiltratePRO device

Complete kits for multiFiltratePRO

Ci-Ca treatment kits for multiFiltratePRO

Usage of multiFiltratePRO– Kit HDF 1000

multiFiltratePRO kit guideline chart

Large and adjustable monitor

Advanced graphic user interface

multiFiltratePRO interface
multiFiltratePRO interface

The multiFiltratePRO includes a graphic user interface that monitors and displays all relevant set-up and treatment data. The integrated alarm system helps to quickly determine the urgency as well as the root cause of alarms.

The time until the next expected user action is displayed in the status bar at the top right of the screen. In addition, a list of further upcoming user interactions can be retrieved on the screen. Both help to optimize work processes in the ICU.

The “Care Button” switches the multiFiltratePRO into care-mode, by decreasing the blood flow, stopping the balancing system and extending the pressure limits. This will prevent unnecessary alarms when moving the patient or manipulating the catheter.

Easy application of CRRT

Related content

1 KDIGO Clinical Practice Guideline for Acute Kidney Injury. Kidney International Supplements 2012. 2:1-138
2 Morgera S et al., A safe citrate anticoagulation protocol with variable treatment efficacy and excellent control of the acid-base status. Critical Care Medicine 2009. 37:2018-24
3 Morgera S et al., Metabolic complications during regional citrate anticoagulation in continuous venovenous hemodialysis: single-center experience. Nephron Clinical Practice 2004. 97:c131-6
4 Kalb R et al., Regional citrate anticoagulation for high volume continuous venovenous hemodialysis in surgical patients with high bleeding risk. Therapeutic Apheresis and Dialysis 2013. 17:202-12